DVC-4 SINE SPECIFICATIONS.
Signal Inputs: Four identical channels, 20 Vp-p maximum input, settable from 5-1000 mV/g. Any can be either control or monitor. |
Sweep Modes: Continuous up to 9999 cycles, half-cycle, or manual control. In Logarithmic, Linear, or Mil 167. |
Current Sources: Four, 4 MA each input, 18-vdc compliance, software selectable. |
Sweep Rates: 0.1 to 9.99 Oct/min logarithmic or 0.1 to 99.9 Hz/sec for linear sweeps. |
Frequency Range: 2 to 10,000 Hz digitally synthesized. |
Signal Output: Servo Out: 0-5 Vrms for amplifier drive, short protected. |
Stability: +/- 100-ppm/C crystal controlled. |
Test Profiles: Up to 32 frequency breakpoints or levels of D, V, or A may be specified for each test, or stored on disk for reuse. |
Distortion: <0.5% THD, 0.25% typical. |
Dwell Points: Two dwell frequencies and dwell times may be specified. |
Limits: Sweeps between programmed upper and lower limits. |
Remote Control: Run, Hold, Servo On, Abort, 5 volt logic activated by switch closure to ground. |
Servo Compressor : |
Display Monitor : |
Dynamic Range: > 70 dB. |
Sweep: Frequency, direction, rate (logarithmic or linear), lower & upper Limit, sweep count. |
Control Accuracy: <0.5 dB nominally. |
Compressor: Rate, speed, and dB of compression. |
Compression Rate: Slow/Medium/Fast = 0.1/0.3/1.0 dB/Sec/Hz. |
Acceleration: From 0 to 200 g-peak or M/sec^2. |
Control Limits: From 0.2 to 200 g with 10-mV/g input. |
Velocity: From 0 to 200 in/sec (IPS) or CM/sec. |
Displacement: From 0 to 9999 Mils or MM p-p. |
|
Time: Time, date, and test run time. |
|
Test Article Protection |
|
Abort Limits: User settable abort limits 1 to 99 dB with soft shutdown. |
Test Documentation : Any of the following plots can be stored on disk or printed out in color or monochrome on any Windows compatible printer. |
Overall Limits: Overall system D, V, and A limits are settable by user. |
Control Profile: The control profile that was entered in. |
Control Signal Loss: Open loop and low gain detector. |
Abort Limits: Upper and lower abort limit lines. |
Manual Abort: From keyboard, mouse or optional remote panel. |
Ch#1 Control/Monitor Channel: Response spectrum of channel #1. |
Ch#2 Control/Monitor Channel: Response spectrum of channel #2. |
|
Ch#3 Control/Monitor Channel: Response spectrum of channel #3. |
|
Ch#4 Control/Monitor Channel: Response spectrum of channel #4. |