DVC-4 SINE SPECIFICATIONS.

 Signal Inputs: Four identical channels, 20 Vp-p maximum input, settable from 5-1000 mV/g. Any can be either control or monitor.

 Sweep Modes: Continuous up to 9999 cycles, half-cycle, or manual control. In Logarithmic, Linear, or Mil 167.

 Current Sources: Four, 4 MA each input, 18-vdc compliance, software selectable.

  Sweep Rates: 0.1 to 9.99 Oct/min logarithmic or 0.1 to 99.9 Hz/sec for linear sweeps.

 Frequency Range: 2 to 10,000 Hz digitally synthesized.

 Signal Output: Servo Out: 0-5 Vrms for amplifier drive, short protected.

 Stability: +/- 100-ppm/C crystal controlled.

 Test Profiles: Up to 32 frequency breakpoints or levels of D, V, or A may be specified for each test, or stored on disk for reuse.

 Distortion: <0.5% THD, 0.25% typical.

 Dwell Points: Two dwell frequencies and dwell times may be specified.

 Limits: Sweeps between programmed upper and lower limits.

 Remote Control: Run, Hold, Servo On, Abort, 5 volt logic activated by switch closure to ground.

Servo Compressor:

Display Monitor:

 Dynamic Range: > 70 dB.

 Sweep: Frequency, direction, rate (logarithmic or linear), lower & upper Limit, sweep count.

 Control Accuracy: <0.5 dB nominally.

 Compressor: Rate, speed, and dB of compression.

 Compression Rate: Slow/Medium/Fast = 0.1/0.3/1.0 dB/Sec/Hz.

 Acceleration: From 0 to 200 g-peak or M/sec^2.

 Control Limits: From 0.2 to 200 g with 10-mV/g input.

 Velocity: From 0 to 200 in/sec (IPS) or CM/sec.

 Displacement: From 0 to 9999 Mils or MM p-p.

 Time: Time, date, and test run time.

Test Article Protection

 Abort Limits: User settable abort limits 1 to 99 dB with soft shutdown.

Test Documentation: Any of the following plots can be stored on disk or printed out in color or monochrome on any Windows compatible printer.

  Overall Limits: Overall system D, V, and A limits are settable by user.

 Control Profile: The control profile that was entered in.

 Control Signal Loss: Open loop and low gain detector.

 Abort Limits: Upper and lower abort limit lines.

 Manual Abort: From keyboard, mouse or optional remote panel.

 Ch#1 Control/Monitor Channel: Response spectrum of channel #1.

 Ch#2 Control/Monitor Channel: Response spectrum of channel #2.

 Ch#3 Control/Monitor Channel: Response spectrum of channel #3.

 Ch#4 Control/Monitor Channel: Response spectrum of channel #4.

BACK